Testing and inspection
As wafer testing continues, aluminum debris from the pads and the like accumulates on the probe tips. What is done periodically in response?
- AThe probe tips are cleaned, for example with an abrasive sheet
- BThe needles are oiled
- CThe needles are bent
Show answer and explanation
Answer: A. The probe tips are cleaned, for example with an abrasive sheet
Debris and oxide on the tips raise contact resistance, preventing accurate measurement and causing good chips to be judged defective. After testing a set number of chips, the tips are therefore scrubbed on an abrasive sheet or similar to clean them and stabilize contact.
- A. Correct. The tips are cleaned periodically.
- B. Oil would cause poor contact and contamination.
- C. Bending the needles would prevent proper contact.