What is HTOL (high-temperature operating life test)?
A reliability test that operates products at high temperature under voltage for a long time to accelerate and evaluate chip lifetime and failure rate. A typical condition is 1000 hours at around 125 °C.
Japanese name: HTOL(高温動作寿命試験)
HTOL (high-temperature operating life test) appears in 4 practice questions across 1 topic, including Reliability.
Field: Reliability
Typical test conditions
Typical conditions are a junction temperature of around 125 °C, a supply voltage at or somewhat above the maximum operating voltage, and a duration of 1000 hours. Conditions like these are typical in JEDEC standards (the JESD22 series), and the automotive AEC-Q100 requires, for example, zero failures when 77 units from each of 3 lots are tested for 1000 hours, with higher temperatures for some temperature grades. High-power products can self-heat to excessive junction temperatures, so the oven temperature is lowered or devices are temperature-controlled individually to hit the target. Parts are pulled and measured at intermediate points such as 168 and 500 hours to track how degradation progresses.
Estimating failure rate from the results
HTOL results are converted to time under use conditions by estimating a temperature acceleration factor with the Arrhenius model and a voltage acceleration factor with a voltage model. For example, assuming an activation energy of 0.7 eV, one hour at 125 °C corresponds to roughly 80 hours at 55 °C. From a zero-failure result, the chi-square distribution gives an upper bound on the failure rate in FIT at a chosen confidence level. Activation energy differs by failure mechanism, however, and the assumed value changes the result greatly, so the figures are treated as estimates.
FAQ
What does HTOL stand for?
High temperature operating life. Parts are operated continuously at high temperature under voltage to accelerate and evaluate chip lifetime and failure rate.
What is the difference between HTOL and burn-in?
Burn-in is a screen that removes early-failure units from products to be shipped, applied for a short time to many units. HTOL is a qualification test that confirms long-term lifetime on a sample, and the tested units are not shipped.
How long does an HTOL test run?
1000 hours is a common benchmark, with measurements at intermediate points such as 168 and 500 hours. Temperature, voltage and duration depend on the applicable standard, the product's temperature grade and agreements with the customer.