To analyze metal contamination on a wafer surface with high sensitivity, which preparation method dissolves the surface oxide with hydrofluoric acid vapor and collects it in a droplet for analysis?
- AFour-point probe
- BSEM observation
- CVPD (vapor phase decomposition)
Show answer and explanation
Answer: C. VPD (vapor phase decomposition)
VPD (vapor phase decomposition) uses HF vapor to decompose the native oxide on the wafer surface and gathers the surface metal impurities into a droplet. Analyzing the collected liquid with ICP-MS or similar allows trace metal contamination over the whole wafer to be measured with high sensitivity.
- A. The four-point probe measures resistivity.
- B. SEM shows surface shape and is not suited to quantifying trace metals.
- C. Correct. Surface contamination is gathered into a droplet for analysis.