Ion implantation

In an ion implanter, which component measures the beam current to determine the number of implanted ions (dose)?

  1. AFaraday cup
  2. BMicrolens
  3. CPellicle
Show answer and explanation

Answer: A. Faraday cup

A Faraday cup catches the ion beam and measures its charge as a current. Since the charge per ion is known, integrating the current over time gives the number of implanted ions, that is, the dose.

Practice this topic Back to topic

More Ion implantation questions

  1. When forming shallow p-type junctions, what is the main purpose of implanting carbon or similar species together with boron (co-implantation)?
  2. Which gas is typically used in the ion source of an implanter to produce boron ions?
  3. Which is an example of an application of high-energy ion implantation reaching several MeV?
  4. If dopants with a dose of 1×10¹⁵ cm⁻² are distributed uniformly over a depth of 100 nm, what is the approximate average concentration?