System Architecture and Reliability

The servers of a semiconductor fab's manufacturing execution system (MES) are made a duplex system consisting of a primary (active) system and a standby system. Which is a characteristic when the standby system is a hot standby?

  1. AThe standby system is kept running and the primary's data is always reflected to it, so processing can switch over in a short time when the primary fails
  2. BThe standby system is kept powered off and is started and has its data restored after the primary fails, so switching over takes time, but power and cost while waiting are kept low
  3. CThe primary and standby systems perform the same processing at the same time and operate while comparing the results
Show answer and explanation

Answer: A. The standby system is kept running and the primary's data is always reflected to it, so processing can switch over in a short time when the primary fails

A hot standby keeps the standby system running and always reflects the primary's data to it, so it can take over processing in a short time when the primary fails. If the MES stops, the fab can no longer direct how lots move, specify recipes to equipment or record manufacturing history, so a configuration that can switch over in a short time is generally chosen. Keeping the standby stopped and starting it after a failure is a cold standby, and the intermediate case (running, but needing preparation before taking over processing) is called a warm standby. Performing and comparing the same processing on two systems at the same time is a dual system.

  • A. Correct. The standby is kept running with its data synchronized, so it can switch over immediately.
  • B. This describes a cold standby.
  • C. This describes a dual system.
Practice this topic Back to topic

Related calculators

Books on System Architecture and Reliability Ad

As an Amazon Associate I earn from qualifying purchases.

More System Architecture and Reliability questions

  1. A system has two redundant load balancers, three web servers behind them, and a single database server used by all the web servers. Among the devices listed here, which is a single point of failure (a point whose stopping stops the whole system)?
  2. A cluster in an active-active configuration shares processing evenly among five servers. Utilization is proportional to the amount of processing. The goal is to keep each server's utilization at 80% or less even when one server fails and the remaining four take over its processing evenly. Which is the upper limit of each server's utilization in normal operation (all five running)?
  3. A system uses three servers with an availability of 0.95 each and has the required capacity as long as at least two of them are running. The servers fail independently, and failures of devices other than the servers are ignored. Which is the availability of this system?
  4. Which is an example of a design based on the fail-soft concept?
  5. In semiconductor manufacturing equipment, normally closed gas supply valves that open with air pressure are used, so that if a power outage or a loss of compressed air occurs, the valves close and the supply of hazardous gas stops. Which design concept is this?