Power Electronics Circuits

Assume that the power lost during a transition is, on average, half of voltage × current. For a power device switching 400 V and 10 A with turn-on and turn-off transition times of 50 ns each and a switching frequency of 100 kHz, which of the following is closest to the switching loss?

  1. A10 W
  2. B20 W
  3. C40 W
Show answer and explanation

Answer: B. 20 W

The energy lost in one transition is (1/2) × V × I × t, so turn-on and turn-off together lose (1/2) × 400 × 10 × (50 + 50) ns = 200 µJ per period. Multiplying by the number of periods per second (100 kHz) gives a switching loss of 200 µJ × 100,000 = 20 W. Switching loss is proportional to frequency, so at 200 kHz it rises to 40 W. SiC and GaN devices, which switch faster, and soft switching are ways to reduce this loss.

  • A. This counts only one of the two transitions. Each period has both a turn-on and a turn-off.
  • B. Correct. (1/2) × 400 × 10 × 100 ns × 100 kHz = 20 W.
  • C. This uses V × I instead of V × I/2 for the power during the transition.
Practice this topic Back to topic

Related calculators

Books on Power Electronics Circuits Ad

As an Amazon Associate I earn from qualifying purchases.

More Power Electronics Circuits questions

  1. In a DC-DC converter, which of the following correctly combines the main reason efficiency drops sharply at very small load currents with a countermeasure?
  2. In a power supply that makes DC from the AC mains, which of the following is the main reason isolated converters, which isolate input from output with a transformer, are used?
  3. Which of the following correctly describes the operation of a flyback converter?
  4. In a forward converter, which of the following correctly explains why a transformer reset winding (or a clamp circuit) is needed?
  5. In sinusoidal PWM for an inverter, which of the following correctly describes how the switches are turned on and off?

Comparisons in this topic